I Need More Information

Our team will be in touch as soon as possible to discuss your needs.

Thank you for your message. It has been sent.
There was an error trying to send your message. Please try again later.

Thermal Paint

Interior-Exterior Heat Insulation Paint 

THERMAL PAINT is an elastomeric resin-based, contains special vacuum microspheres, have vapor-permeability, water-based, a low thermal conductivity, high sunlight absorbency, and high surface heat transmission value. Its activity is scientifically proved special insulating paint which provides the thermal and water insulation in the interior and exterior facades. It provides energy savings to buildings of up to 40% depending on the application layers number in heating and cooling energy costs. When the ISONEM THERMAL PAINT with special vacuum microspheres is used as interior wall paint, it reflects the radiant heat generated inside to the interior environment, and when it is used on the exterior, the incoming radiant heat is reflected back to the outside. When used on roofs, it reflects a minimum 80% of the sun’s rays thanks to its ceramic-reinforced formula. While the water never passes from the film surface applied Isonem Thermal Paint, the moisture inside the building evaporates away from the structure.

PROPERTIES

· Radiont heat proof.

· Saves up to 40% energy.

· Applicable to internal and external surfaces.

· Labor costs are low and easy to apply.

· It prevents the formation of moisture and mold in the wall.

· It has water and sound insulation feature.

· It has late flammability and nonflammability.

TECHNICAL SPECIFICATIONS

Density (25°C, g/mL) : 0,85 ± 0,10
pH (25°C) : 7.0 – 9.0
Viscosity (25°C, mPa.s) : 12500 – 13500
Solid content (% Weight) : 53 ± 2
Water transmission rate (kg/ m2. h0,5) : < 0,1 CLASS W3
Adhesion strength by pull-off test (N/mm2) : Crack bridging flexible systems without trafficking ≥ 0.8,
Permeability to water vapour (m) : 5 ≤  SD ≤ 50 CLASS II
Certification : TSE K 127 THERMAL PAINTS
Class : COLD CLIMATE PAINT
Brightness : N/A (not applied)
Wet abrasion resistance (μm) : CLASS II
Covering power (m2/L) : CLASS I
Dry film thickness : CLASS E5
Grain size : CLASS S2
Crack covering feature (μm) : not required, CLASS A0
Carbon dioxide permeability (g/m2.d) : not required, CLASS CO
Surface heat transmission value (Ԑ) : min. 0.80
Sunlight absorbency value (α) : 0.820, min. 0.80
Thermal paint surface resistance (RS) : 0.0495 ± 1,5 %
Heat conductivity coefficient (W/mK) : 0.023, λ<0.060
Impact resistance : no cracking & rupture
Solvent : Water
Documents of the ProductDOCUMENTS OF THE PRODUCT
Application Video Application Video

Surface preparation: Surfaces to be applied should be free of dirt, oil, paste, grease, loose parts and other foreign materials. The appropriate primer selection for surface is made according to the following table. ISONEM UNIVERSAL PRIMER (1: 7 diluted with water – 1 part primer, 7 part water) insulation and paint primer should be applied one layer with 100 – 200 g/m² consumption. The primer is then allowed to dry for 4 hours.

Application method: ISONEM THERMAL PAINT must be mixed thoroughly before use. In exterior applications, 2 to 3 coats can be applied by roller or brush without diluting the product. It should be applied as 1 or 2 coats according to color and hiding power. It is recommended to apply 2 – 3 coats in roof applications. It is recommended that each coat be painted perpendicular to the previous coat. It can be applied by taking into consideration the drying processes. The second and third layer should be applied after the first layer has dried. Wait for 4 hours between two coats.

COLOR: All requested can be produced in colors

PACKING: 5 L, 10 L and 18 L PP bucket.

CONSUMPTION: max. 300 mL/m² (in interior applications), 1 L/m² (for 1 mm thickness), 2 L/m² (for 2 mm thickness)

PAINTABLE (COVERAGE) AREA: 5 L: 3,5 – 5 m²/bucket, 10 L: 7 – 10 m²/bucket, 18 L: 12 – 18 m²/bucket

SHELF LIFE: 24 months from date of production if stored in original, unopened, undamaged packages.

STORAGE CONDITIONS: Store tightly closed in a dry and cool place.

IMPORTANT: Consuming more or less can lead to inefficiency and side effects.

The surface should be protected from rain, water, mechanical loads and impacts for 24 hours during and after the application.